Please follow the steps below to replace the IQ Panel 2 backup battery: 

 

1. Swipe down from the time display to open the Settings drop-down, then press SETTINGS

Enter_Program_01_Main.jpg Enter_Program_02_Dropdown.jpg

 

2. Press ADVANCED SETTINGS, then enter your Master Code

Enter_Program_03_Settings_Menu.jpg Enter_Program_04_Enter_Code.jpg

 

3. Press POWER DOWN, then OK to confirm. The IQ Panel 2 will power down.

Power_Down_01.jpg Power_Down_02.jpg

 

4. Remove the bottom screw, then press both bottom tabs to remove the front cover

IQ_Panel_2_Bottom.jpg

 

5. Rotate the front cover down and hang strap onto backplate

IQ_Panel_2_Hanging.jpg

 

6. Unplug the battery connector from the circuit board, then pull the blue battery tab to remove

Battery_Replace.jpg

 

7. Remove adhesive from the new battery, stick into case and plug in the connector

 Battery_Remove.jpg

 

8. Fasten front cover to the backplate, then hold the right side button for 3 to 4 seconds to power back up

Power_Button.jpg 