Honeywell Lynx Plus - Deleting a Sensor

1. Enter  the Installer Code 4112 then press 800, keypad displays 20 INSTALLER CODE

                                                      

1. Enter Zone 01 to 99 to delete then press *

 Lynx_Plus_Then.jpg 

2. Enter 00 for Zone Type then press *

 Lynx_Plus_Then.jpg 

3. Press 1 to delete then press 00 to exit

 Lynx_Plus_Then.jpg  Lynx_Plus_Then.jpg 

4. Press *99 to exit programming

 Lynx_Plus_Then.jpg 

 

Was this article helpful?
1 out of 1 found this helpful

Comments

2 comments
  • My system was installed by ADT and this procedure didn't work.

  • Larry, if you've not figured it out by now, ADT might have changed the installer code, try the following:

     

    Within 50 seconds of power-up, press the * and # keys at the same time. The display should show “20”.

    Press # + 2 + 0. The display will scroll through the current 4-digit installer code. Jot this down. (Note: The display shows single digits with a leading zero, so 01 = 1, 02 = 2, etc.). 


    To change the installer code, press *20, followed by a new 4-digit installer code. 


    Exit programming mode by pressing *99.