DSC Silence And View System Troubles

LED and Fixed English LCD Keypads

Yellow Triangle Trouble LED turns ON and keypad beeps every 10 seconds, press # to silence

Press * 2 to view troubles, sensor light turns ON indicating trouble then press # to exit

Zone Light 1 = Service Required, press 1 to show exact trouble

  • Light 1 = Low Panel Battery
  • Light 2 = Siren Trouble
  • Light 3 = General System Trouble (External module trouble)
  • Light 4 = General System Tamper (External module tamper)
  • Light 5 = General System Supervisory (Lost communication with module)
  • Light 6 = RF Jamming (Wireless receiver is being jammed by outside source)
  • Light 7 = 5204 Power Supply Module Low Battery
  • Light 8 = 5204 Power Supply Module AC Failure

Zone Light 2 = AC Failure

Zone Light 3 = Telephone Line Trouble (Phone line trouble)

Zone Light 4 = Failure to Communicate (Over phone line)

Zone Light 5 = Zone Fault / Trouble, press 5 to show Zone (Usually dead battery or bad sensor)

Zone Light 6 = Zone Tamper, press 6 to show Zone (Usually sensor cover loose or off)

Zone Light 7 = Zone Low Battery, press 7 to show which Zone

  • Press 7 again for Keypad low batteries
  • Press 7 again for Keyfob low batteries

Zone Light 8 = Loss of System Clock (See Set Time & Date)

Alphanumeric LCD Keypads

Yellow Triangle Trouble LED turns ON, keypad beeps every 10 seconds, press # to silence

1. Press * then 2 then scroll troubles with < or > buttons, press # to exit and silence trouble beeps

  

2. Some Troubles like Low Batteries or Module Tampers require pressing * to view

 

3. Some Troubles like Zone Faults, Tampers or Low Batteries require pressing * to view

 

Was this article helpful?