2GIG-RPTR1-345 Wireless Repeater

2GIG-RPTR1-345_Repeater_Top.jpg

Specification

  • Repeats 345 MHz 2GIG and Honeywell sensors
  • 24-hour backup battery
  • RF Range 100' from panel or wireless sensors
  • Operating temperature 14° F to 131° F
  • 14-Volt 1700 mA DC power supply
  • 14500 3.7-Volt 800 mA Lithium battery (up to 24-hour backup)

Panel Compatibility 

  • 2GIG GC2 Go Control v1.16 and higher
  • 2GIG GC2e
  • 2GIG GC3 v3.1 and higher
  • 2GIG GC3e

Sensor Compatibility

  • Compatible with most 245 MHz 2GIG and Honeywell wireless sensors
  • Not compatible with 2GIG TS-1 Touchscreen

Status LED

  • Green ON = Power and battery OK
  • Red ON = Tamper or power failure
  • Red slow flash = Low battery
  • Red fast flash = RF Jamming
  • Blink OFF = Transmission received

2GIG-SDS1-345 Smoke Detector

2GIG-SDS1-345_Smoke_Ring_2_jpg.jpg

Specification

  • Converts existing hardwire smoke detectors to 2GIG or Honeywell wireless sensors
  • Only 1 sensor is needed on interconnected smoke detectors
  • Sends Smoke Alarm + SDS1-345 Low Battery, Tamper/Supervisory messages
  • 345 MHz sends supervisory signal every 70 minutes
  • Operating temperature 40° F to 100° F
  • CR2032 3-Volt Lithium battery, up to 3 year estimated battery life
  • 7-day battery life if AC power fails

Panel Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

2GIG-TS-1 Touchscreen

2GIG-TS1_v1_Touchscreen_Front_with_Display.jpg

Information

  • 4 touchscreens per system
  • Display is identical to Go Control panel
  • 918.872 MHz (Zigbee) requires 2GIG-XCVR2-345 Bi-directional transceiver module
  • OTA firmware updates from Alarm.com website will update both Go Control and TS-1
  • Local updates require 2GIG USB CABLE with pins to update TS1
  • RF Range up to 100' from panel
  • Operating temperature 32° F to 120° F
  • 9 to 14-Volt 2GIG-AC1 DC power supply
  • TS-1 version 1 = 3 AA Alkaline batteries
  • TS-1 version 2 = No batteries, plug-in transformer connector

Compatibility 

  • 2GIG GC2 Go Control v1.8.1 and higher
  • 2GIG GC2e

2GIG-TILT1-345 Tilt Sensor

2GIG-TILT1-345_Tilt_Sensor.jpg

Specifications

  • Activates if tilted 45 degrees from vertical
  • 5-second delay between activation and panel displaying open zone
  • 345 MHz sends a supervisory signal every 70 minutes
  • RF Range up to 100' from panel
  • Operating temperature 2° F to 120° F
  • CR2032 3-Volt Lithium battery, 5 to 8 year estimated battery life

Compatibility 

  • 2GIG GC2 Go Control v1.14 and higher
  • 2GIG GC2e
  • 2GIG GC3 v3.1.1 and higher
  • 2GIG GC3e

Programming 

  • Tilt 5 seconds to learn
  • Program as a door sensor
  • Sensor Type: Entry Exit 1 or Entry Exit 2
  • Equipment Code: 1062 2GIG Tilt Sensor
  • Loop 1

 2GIG-TAKE-345 Superswitch Wireless Converter

sswitch.JPG

Specifications

  • Converts 8 hardwire zones 8 2GIG compatible wireless zones
  • Receives power from old alarm panel backup battery 
  • 2GIG-TAK-KIT1 combines TAKE345 with enclosure and Altronix power supply
  • 345 MHz sends a supervisory signal every +7
  • RF range up to 100' from panel
  • Operating temperature 32° F to 120° F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

2GIG-STVGRL1-345 Stove and Grill Detector

2GIG-STVGRL1-345_Stove___Grill_Guard_01.png

Specifications

  • Notifies if knob on grill or stove is left in ON position
  • Non-replaceable internal Lithium, up to 5 year battery life
  • RF Range up to 100' from panel
  • Operating temperature 14° F to 167° F

Compatibility 

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e
  • Honeywell Lynx
  • Honeywell Lyric
  • Honeywell Vista

Installation

  • Remove knob and clean grill surface
  • Apply supplied adhesive strips to back to Grill Guard sensor
  • Stick sensor on grill base
  • Insert sleeve over knob stem, sleeve magnet must line up with alignment marks while knob is in OFF position

2GIG-SMKT3-345 Smoke Heat Detector


2GIG-SMKT3-345_Smoke_Heat_Detector_Top_03.jpg 2GIG-SMKT3-345_Smoke_Heat_Detector_Bottom_03.jpg 

Specifications

  • Smoke detector with integrated heat and freeze sensors
  • 35' protection area
  • Freeze detector activates below 41 degrees
  • Heat detector activates above 135 degrees
  • 345 MHz sends supervisory signal every 70 minutes
  • Trouble beeps can be silenced for 12 hours with test button
  • 3 AAA Alkaline, 2 to 3 year estimated battery life
  • 35' detection range
  • RF range up to 100' from panel panel
  • Operating temperature 40° F to 100° F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

 Testing

  • Press and release Test button to test smoke sounder
  • Hold Test button 20 seconds to trigger smoke detector test to panel

Status LED

  • Normal = Green flash every 12 seconds
  • Alarm = Red flash every second, 3-tone sounder
  • Dirty Element = Yellow blink every 8 seconds, sounder chirp every 48 seconds
  • Trouble = Yellow blink every 4 seconds, sounder chirp every 48 seconds
  • Low Battery = Yellow flash every 12 seconds, 1 chirp every 45 seconds
  • Freeze =  3 Yellow blinks every 4 seconds, no sounder
  • Tamper = Red, yellow, and green flash every 12 seconds